Medium 30 minutes 27.01.2026

Connecting the CAN bus to ASN BOTHERTZ-24

How to pull telemetry from the factory bus: choosing a profile, connecting via DTA and verifying the data stream.

For equipment: ASN BOTHERTZ-24
Regulations: №2216 №1378

Two ways to connect

BG24-ASN-M2 receives data from the CAN bus in two ways:

Method How it is connected When to use
External DTA reader Over RS-485 Minimal installation is needed, no configuration required
Built-in CAN CAN_H / CAN_L directly Access to parameters is needed without a separate reader

When using the DTA, no additional configuration is required: once connected, data starts flowing to the monitoring system automatically.

Built-in CAN: what to prepare

To work with the built-in interface you need external power or a charged battery — without power the device may not be recognised as a USB device. The bus configuration file is issued by technical support; there is no universal profile, the parameter set depends on the vehicle model.

The 'Activate built-in CAN' checkbox in the configurator system settings
The built-in CAN activation checkbox in the system settings.

Once the configuration is loaded, connection is made by pinout: CAN_H — to CAN High, CAN_L — to CAN Low, GND — to ground. Before connecting, turn off the ignition and check the polarity.

Verifying the stream

Data is displayed in the local configurator on the "Monitoring" tab and in the monitoring system — via the AO GLONASS repeater. The full list of CAN parameters is given in the "Data transmission" section of the documentation.

Instruction

Step-by-step procedure

Time to complete: 30 minutes

  1. Choose the connection method

    Via an external DTA reader over RS-485 — no additional configuration is needed. Or directly via the built-in CAN interface — the bus must be activated and a configuration loaded.

  2. Connect the DTA if you use a reader

    Connect the DTA to the unit over RS-485 and apply power. Data starts flowing to the monitoring system automatically, without configuring a profile.

  3. Activate the built-in CAN

    In the local configurator open "Settings → System" and enable "Activate built-in CAN". Via SMS this is command 123456*PSET*5421,1; to check the state — 123456*PGET*5421.

  4. Load the bus configuration

    Get the configuration file from technical support, connect the unit to a PC over USB and in the configurator select "Commands → Update CAN program locally". The configurator loads the file and reboots the device.

  5. Connect to the bus and check the data

    With the ignition off, connect CAN_H of the unit to CAN High, CAN_L to CAN Low and GND to the vehicle ground. Turn the ignition on and after 5–15 seconds check the parameters on the "Monitoring" tab.

If it does not work

Possible errors

No telemetry is coming in

Check that the ignition is on: with the engine off some parameters are not transmitted. For the built-in CAN, make sure a configuration file for your vehicle model is loaded.

Individual parameters drop out

Request an updated parameter map for the specific model and model year: manufacturers change the PGN set.

The unit does not see the bus

Check the polarity and integrity of the line, the resistance should be about 60 Ohm between CAN-H and CAN-L. A damaged twisted pair is a common cause.

Sources

  • docs.duotec.ru/99/can.html — "CAN setup", accessed 17.11.2026
  • bothertz.ru/equipment — "ASN" section, accessed 17.11.2026

Reviewed: 17.11.2026